#278 closed defect (fixed)
changeset 919 issue with multiple protocol and not pts with some readers
Reported by: | dpeddi | Owned by: | |
---|---|---|---|
Priority: | major | Component: | |
Severity: | medium | Keywords: | |
Cc: | Sensitive: | no |
Description
card: videoguard2 caid 919 and 93b
reader: smartreader2 in smartmouse mode
code with problem:
if (NeedsPTS) {
if (OffersT[0]) {
pps->parameters.t = ATR_PROTOCOL_TYPE_T0;
pps->parameters.FI = ATR_DEFAULT_FI;
pps->parameters.d = ATR_DEFAULT_D;
}
}
I think it should be
if (NeedsPTS) {
if (OffersT[0]) {
pps->parameters.t = ATR_PROTOCOL_TYPE_T0;
pps->parameters.FI = ATR_DEFAULT_FI;
pps->parameters.d = ATR_DEFAULT_D;
}
}
2009/12/31 0:21:08 17047 r03 Protocol 1: TA1=13 TB1=25 TC1=02 TD1=50 (T0)
2009/12/31 0:21:08 17047 r03 Protocol 2: TA2=80 TC2=0F no TD2 means T0
2009/12/31 0:21:08 17047 r03 1 protocol types detected. Historical bytes: 33 B0 13 69 FF 4A 50 D0 80 00 49 54 03
2009/12/31 0:21:08 17047 r03 PTS: Sending request: FF 10 13 FC
2009/12/31 0:21:09 17047 r03 PTS Failure for protocol 1, response:
2009/12/31 0:21:09 17047 r03 PTS: Sending request: FF 10 80 6F
2009/12/31 0:21:10 17047 r03 PTS Failure for protocol 2, response:
2009/12/31 0:21:10 17047 r03 No PTS happened, selected protocol 1: T0, F=372, D=1.000000, N=2
correct values that enable card readings are:
T0, F=372, D=4.000000, N=2
I get these parameter back by disable commenting out code above
Change History (2)
comment:1 by , 14 years ago
comment:2 by , 14 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
should be solved with changeset "1061"...