id summary reporter owner description type status priority component severity resolution keywords cc sensitive 4534 Error when writing EMM with Polsat Cyfrowy (caid 1861) FrogDR "= Revision every revision over r11163 = Issue Description 2016/11/11 18:33:50 2CDEEE09 r (reader) polsat [nagra] T1 Resync command error, trying to reactivate! 2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] ATR: 3F FF 95 00 FF 91 81 71 A0 47 00 44 4E 41 53 50 31 38 30 20 4D 65 72 30 30 30 28 2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] Init card protocol T1, FI=9, F=512, D=16, N=255 2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] Calculated work ETU is 7.11 us reader mhz = 450 2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] Buffers readed 0 bytes total time_us 3099355 2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] PLL Reader: ATR Fsmax is 5 MHz, clocking card to 4.50 Mhz (nearest possible mhz specified reader->mhz) 2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] Card responded ok for ifsd request of 160 = When the issue occurs everytime when EMM goes to a card i`v got error like i write up. = How the issue is reproducable about every 3min... R11163 is the latest works without this error. I check what was a changeset in R11164 : ""Message: NAGRA: Additional EMM filtering for emms starting with 0x84 and 0x87 as used by e.g. MaxTV Tnx goes to Pr2 for delivering initial patch, I merely reworked it a bit so that not 3 additional filters will be setup!"" So something gose wrong with this update...." defect closed major Card support high fixed emm write error polsat cyfrowy 0